2-449
Catalyst 3560 Switch Command Reference
78-16405-05
Chapter 2 Catalyst 3560 Switch Cisco IOS Commands
show ipv6 mld snooping querier
Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output
do not appear, but the lines that contain Output appear.
Examples This is an example of output from the show ipv6 mld snooping querier command:
Switch> show ipv6 mld snooping querier
Vlan IP Address MLD Version Port
-------------------------------------------------------------
2 FE80::201:C9FF:FE40:6000 v1 Gi0/1
This is an example of output from the show ipv6 mld snooping querier detail command:
Switch> show ipv6 mld snooping querier detail
Vlan IP Address MLD Version Port
-------------------------------------------------------------
2 FE80::201:C9FF:FE40:6000 v1 Gi0/1
This is an example of output from the show ipv6 mld snooping querier vlan command:
Switch> show ipv6 mld snooping querier vlan 2
IP address : FE80::201:C9FF:FE40:6000
MLD version : v1
Port : Gi0/1
Max response time : 1000s
Related Commands2
Command Description
ipv6 mld snooping Enables and configures IPv6 MLD snooping on the switch or on
a VLAN.
ipv6 mld snooping
last-listener-query-count
Configures the maximum number of queries that the switch
sends before aging out an MLD client.
ipv6 mld snooping
last-listener-query-interval
Configures the maximum response time after sending out a
query that the switch waits before deleting a port from the
multicast group.
ipv6 mld snooping
robustness-variable
Configures the maximum number of queries that the switch
sends before aging out a multicast address when there is no
response.
sdm prefer Configures an SDM template to optimize system resources
based on how the switch is being used.