EasyManua.ls Logo

Cisco WS-C3560E-24PD-E

Cisco WS-C3560E-24PD-E
914 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2-651
Catalyst 3560 Switch Command Reference
78-16405-05
Chapter 2 Catalyst 3560 Switch Cisco IOS Commands
system env temperature threshold yellow
system env temperature threshold yellow
Use the system env temperature threshold yellow global configuration command to configure the
difference between the yellow and red temperature thresholds which determines the value of yellow
threshold. Use the no form of this command to return to the default value.
system env temperature threshold yellow value
no system env temperature threshold yellow value
Syntax Description
Defaults These are the default values:
Command Modes Global configuration
Command History
Usage Guidelines Though visible on all switches, this command is only valid on these switches:
Catalyst 3560G-48TS
Catalyst 3560G-48PS
Catalyst 3560G-24TS
Catalyst 3560G-24PS
value Specify the difference between the yellow and red threshold values (in Celsius). The
range is 10 to 25. The default value is 10.
Table 2-37 Default Values for the Temperature Thresholds
Switch
Difference
between Yellow
and Red Red
1
1. You cannot configure the red temperature threshold.
Catalyst 3560G-48TS 10°C 66°C
Catalyst 3560G-48PS 10°C 68°C
Catalyst 3560G-24TS 10°C 65°C
Catalyst 3560G-24PS 10°C 61°C
Release Modification
12.2(25)SE This command was introduced.

Table of Contents

Related product manuals