57
——
Home menu Sub menu Default Congurable range Notes
System Setup Sensor Level 1.5 V 0.0 V to 3.3 V Sets the sensor threshold
Paper End Level 3.00 V 0.01 V to 3.30 V Sets the paper end level
Error Reporting On Printing On Printing
Immediate
Error reporting setting
Buzzer Select Exec/Err Exec/Err
All
Error
Key
None
Sets the conditions at which the
buzzer is triggered
Metric/Inch Inch Inch
mm
Sets the unit of measure
Max Media
Length
10.00 inch
254.0 mm
CL-E321:
(Datamax)
0.25 to 99.99 inch
6.4 to 2539.7 mm
(Zebra)
0.25 to 100.00 inch
6.4 to 2540.0 mm
CL-E331:
1.00 to 50.00 inch
25.4 to 1,270.0 mm
Sets the maximum length of label
media
Settings Lock Off On
Off
Prevents changes via setting com-
mands
Keyboard Lock Off On
Off
Prevents changes via key operation
Control Code STD STD
ALT
ALT-2
Changes the command mode for
DMX mode (only when Datamax®
emulation is selected)
Media Power Up Off On
Off
Sets the media length measuring
function when the power is turned
on (only when Zebra® emulation
mode is selected on international
models)
CI Lock Off On
Off
Prevents changes via CI com-
mands (only when Zebra® emula-
tion mode is selected on interna-
tional models)
Emulation Select DM4
(Datamax®)
ZPI2 (Zebra®)
DM4
DMI
DPP
ZPI2
Datamax®/Zebra® compatibility
selection
DM4 Datamax® 400
DMI Datamax® IClassTM
DPP Datamax® Prodigy Plus®
ZPI2 Zebra® ZPL2 ®
Emulation Auto
Detect
Full Auto On
Off
Full Auto
Sets the emulation sensing function
(international models only)