fn=4: Function 4 Sending the Set Memory Switch Value
GS ( E pL pH fn a
[Code] <1D>H<28>H<45>H<pL><pH><fn><a>
[Range] (pL+pH×256)=2
fn=4
CT-S280
a=1, 2, 3
CT-S300
a=1, 2, 3, 4
CT-S281
a=1, 2, 3, 4, 5, 13
CT-S310/CT-S2000/CT-S4000/CT-P29x series
a=1, 2, 3, 4, 5
CT-S801(II)/CT-S851(II)/CT-S601(II)/CT-S651(II)/CT-S310II/CT-S251/CT-D150/CT-E351/CT-D1
51/CT-E651
a=1, 2, 3, 4, 5, 6
[Outline] [The specification which is common to the model]
• Sends the content of MSW set in “a”.
Hex.
No. of Data
Header
37H
1
ID
21H
1
Data
30H or 31H
8
NULL
00H
1
• Sends the set value of data in 8-byte data raw in order of bits 8, 7, 6
OFF: 30H (0”)
ON : 31H (“1”)
[Caution] [The specification which depend on the model]
CT-S281/CT-S310/CT-S2000/CT-S4000/CT-P29x series/
CT-S801/CT-S851/CT-S601/CT-S601/CT-S310II/CT-D150/CT-E351
MSW7 to MSW10 cannot be sent by this command.
Transmission is available by <Sending preset customize value>.
CT-S801II/CT-S851II/CT-S601II/CT-S651II/CT-D151/CT-E651
MSW7 to MSW10,13 cannot be changed by this command. They can be changed by the
setting of customize value.
CT-S251
MSW7 to MSW10,11,13 cannot be changed by this command. They can be changed by
the setting of customize value.