fn=3: Function 3 Setting Memory Switch Value
GS ( E pL pH fn [a1 b18...b11] ... [ak bk8...bk1]
[Code] <1D>H<28>H<45>H<pL><pH><fn> [<a1><b18><b11>] [<ak><bk8><bk1>]
[Range] 10(pL+pH×256)65535
fn=3
b=48, 49, 50
CT-S280
a=1, 2, 3
CT-S300
a=1, 2, 3, 4
CT-S281
a = 1, 2, 3, 4, 5, 13
CT-S310/CT-S2000/CT-S4000/CT-P29x series
a = 1, 2, 3, 4, 5
CT-S801(II)/CT-S851(II)/CT-S601(II)/CT-S651(II)/CT-S310II/CT-S251/CT-D150/CT-E351/CT-D1
51/CT-E651
a=1, 2, 3, 4, 5, 6
[Outline] [The specification which is common to the model]
• Changes the MSW set in a to the value set in “b”.
B
Function
48
Sets corresponding bit to OFF.
49
Sets corresponding bit to ON.
50
Does not change corresponding bit.
[Caution] [The specification which depend on the model]
CT-S281/CT-S310/CT-S2000/CT-S4000/CT-P29x series/
CT-S801/CT-S851/CT-S601/CT-S601/CT-S310II/CT-D150/CT-E351
MSW7 to MSW10 cannot be changed by this command. They can be changed by the
setting of customize value.
CT-S801II/CT-S851II/CT-S601II/CT-S651II/CT-D151/CT-E651
MSW7 to MSW10,13 cannot be changed by this command. They can be changed by the
setting of customize value.
CT-S251
MSW7 to MSW10,11,13 cannot be changed by this command. They can be changed by
the setting of customize value.