Do you have a question about the CleaverBrooks CBT and is the answer not in the manual?
Description of the boiler's 2-pass vertical tubeless pressure vessel design and construction.
Details on full modulation (CBT-M) and on/off (CBT) burner types, features, and technology.
Overview of the gas train assembly, components, and compliance with certifications.
Explanation of control systems for full modulation and on/off boilers, including abbreviations.
Diagrams illustrating the location of key components and connections on CBT boilers.
List of optional features and accessories available for the Cleaver-Brooks Model CBT Boiler.
Instructions for safely lifting and moving the boiler unit, including cautionary notes.
Guidance on water treatment to ensure boiler effectiveness, lifespan, and prevent damage.
Specifications for the boiler room environment, including ambient conditions and clearances.
Requirements for gas piping installation, pressure, sizing, and sediment traps.
Procedures for making essential waterside connections, including safety valve installation.
Instructions for making electrical connections to the boiler, adhering to codes.
Diagrams illustrating electrical wiring for both full modulation and on/off boiler systems.
Guidelines for flue gas exhaust venting and definition of appliance categories.
Recommendations for flue venting installation, including material and support requirements.
Critical considerations for vent terminal placement to avoid hazards and property damage.
Installation procedures for horizontal through-wall venting using inside air for combustion.
Installation guidelines for direct vent systems where air is drawn from outside.
Specific requirements for terminating horizontal through-wall flue vents.
Installation details for vertical venting systems using inside air for central heating.
Installation for vertical venting systems drawing combustion air directly from outside.
Guidelines for designing flue and combustion air ducts for direct vent systems.
Steps for commissioning full modulation boilers, including operating conditions and controls.
Procedure for filling the boiler with water and checking for leaks prior to operation.
Setting initial safety control parameters before starting the boiler.
Configuration and checks for LWCO and ALWCO controls within the boiler system.
Configuring the CB Falcon boiler control system and its display/operator interface.
Understanding and managing different types of fault conditions in the CB Falcon system.
Detailed guide to configuring CB Falcon controller parameters for specific boiler models.
Explanation of the burner's operating sequence, including ignition and flame supervision.
Guidelines for adjusting fan speed settings based on application and altitude.
Step-by-step guide for the initial startup of the boiler and its systems.
Checks and procedures for the gas train and piping before initial operation.
Steps for powering up the boiler's control and blower circuits.
Verification of gas valve, pressure switches, and air proving switch functionality.
Testing procedures for the Low Water Cut-Off (LWCO) and Auxiliary LWCO (ALWCO) controls.
Procedure for adjusting the boiler's gas valve for low and high fire settings.
Adjusting the parameter that determines when the burner shuts off during modulation.
Steps for properly setting combustion parameters using a combustion analyzer.
Testing the High Limit Control (HLC) and Operating Limit Control (OLC) settings.
Specific steps for commissioning on/off boiler systems.
Procedure for adjusting the ignition system for proper flame detection.
Guidelines for adjusting gas settings for optimal combustion on/off boilers.
Testing to ensure main power does not interfere with flame relay operation.
Recommended steps for cleaning the boiler's interior before initial use.
Final checks and instructions to provide after initial boiler startup.
Summary of CB Falcon control features for steam boilers and customer interface.
Configuration for remote boiler control via discrete and analog inputs.
Recommended maintenance program to ensure safety, efficiency, and longevity.
Instructions for performing bottom blowdown to remove boiler water solids.
Procedure for blowing down the water column and gauge glass for accurate level indication.
Detailed step-by-step guide for the water column and gauge glass blowdown process.
Steps for accessing, cleaning, and inspecting the fireside of the boiler and burner.
Inspection and maintenance procedures for the ignition electrode.
Inspection and cleaning of the UV flame scanner for full modulation burners.
Recommended procedures for inspecting and cleaning the waterside surfaces of the boiler.
Guidelines for inspecting and testing the boiler's safety valve.
Guidance on diagnosing and resolving common boiler operational problems and lockouts.
Using the CB Falcon display for diagnostic features and screen calibration.
Instructions for proper lay-up (dry or wet) to protect boiler surfaces during extended inactivity.
List of recommended spare parts for Cleaver-Brooks Model CBT boilers by HP size.
Specifications and part numbers for safety valves based on boiler HP and set pressure.
Diagrams and part numbers for components within the control panel for full modulation.
Detailed parts breakdown for burner assemblies across different HP sizes and modes.
List and diagrams of parts for the boiler's water column assembly.
Parts list and diagram for the feedwater piping system.
Parts list and diagrams for gas train assemblies in full modulation and on/off configurations.
Kit numbers for direct vent systems available for CBT boilers by HP size.
Description of the boiler's 2-pass vertical tubeless pressure vessel design and construction.
Details on full modulation (CBT-M) and on/off (CBT) burner types, features, and technology.
Overview of the gas train assembly, components, and compliance with certifications.
Explanation of control systems for full modulation and on/off boilers, including abbreviations.
Diagrams illustrating the location of key components and connections on CBT boilers.
List of optional features and accessories available for the Cleaver-Brooks Model CBT Boiler.
Instructions for safely lifting and moving the boiler unit, including cautionary notes.
Guidance on water treatment to ensure boiler effectiveness, lifespan, and prevent damage.
Specifications for the boiler room environment, including ambient conditions and clearances.
Requirements for gas piping installation, pressure, sizing, and sediment traps.
Procedures for making essential waterside connections, including safety valve installation.
Instructions for making electrical connections to the boiler, adhering to codes.
Diagrams illustrating electrical wiring for both full modulation and on/off boiler systems.
Guidelines for flue gas exhaust venting and definition of appliance categories.
Recommendations for flue venting installation, including material and support requirements.
Critical considerations for vent terminal placement to avoid hazards and property damage.
Installation procedures for horizontal through-wall venting using inside air for combustion.
Installation guidelines for direct vent systems where air is drawn from outside.
Specific requirements for terminating horizontal through-wall flue vents.
Installation details for vertical venting systems using inside air for central heating.
Installation for vertical venting systems drawing combustion air directly from outside.
Guidelines for designing flue and combustion air ducts for direct vent systems.
Steps for commissioning full modulation boilers, including operating conditions and controls.
Procedure for filling the boiler with water and checking for leaks prior to operation.
Setting initial safety control parameters before starting the boiler.
Configuration and checks for LWCO and ALWCO controls within the boiler system.
Configuring the CB Falcon boiler control system and its display/operator interface.
Understanding and managing different types of fault conditions in the CB Falcon system.
Detailed guide to configuring CB Falcon controller parameters for specific boiler models.
Explanation of the burner's operating sequence, including ignition and flame supervision.
Guidelines for adjusting fan speed settings based on application and altitude.
Step-by-step guide for the initial startup of the boiler and its systems.
Checks and procedures for the gas train and piping before initial operation.
Steps for powering up the boiler's control and blower circuits.
Verification of gas valve, pressure switches, and air proving switch functionality.
Testing procedures for the Low Water Cut-Off (LWCO) and Auxiliary LWCO (ALWCO) controls.
Procedure for adjusting the boiler's gas valve for low and high fire settings.
Adjusting the parameter that determines when the burner shuts off during modulation.
Steps for properly setting combustion parameters using a combustion analyzer.
Testing the High Limit Control (HLC) and Operating Limit Control (OLC) settings.
Specific steps for commissioning on/off boiler systems.
Procedure for adjusting the ignition system for proper flame detection.
Guidelines for adjusting gas settings for optimal combustion on/off boilers.
Testing to ensure main power does not interfere with flame relay operation.
Recommended steps for cleaning the boiler's interior before initial use.
Final checks and instructions to provide after initial boiler startup.
Summary of CB Falcon control features for steam boilers and customer interface.
Configuration for remote boiler control via discrete and analog inputs.
Recommended maintenance program to ensure safety, efficiency, and longevity.
Instructions for performing bottom blowdown to remove boiler water solids.
Procedure for blowing down the water column and gauge glass for accurate level indication.
Detailed step-by-step guide for the water column and gauge glass blowdown process.
Steps for accessing, cleaning, and inspecting the fireside of the boiler and burner.
Inspection and maintenance procedures for the ignition electrode.
Inspection and cleaning of the UV flame scanner for full modulation burners.
Recommended procedures for inspecting and cleaning the waterside surfaces of the boiler.
Guidelines for inspecting and testing the boiler's safety valve.
Guidance on diagnosing and resolving common boiler operational problems and lockouts.
Using the CB Falcon display for diagnostic features and screen calibration.
Instructions for proper lay-up (dry or wet) to protect boiler surfaces during extended inactivity.
List of recommended spare parts for Cleaver-Brooks Model CBT boilers by HP size.
Specifications and part numbers for safety valves based on boiler HP and set pressure.
Diagrams and part numbers for components within the control panel for full modulation.
Detailed parts breakdown for burner assemblies across different HP sizes and modes.
List and diagrams of parts for the boiler's water column assembly.
Parts list and diagram for the feedwater piping system.
Parts list and diagrams for gas train assemblies in full modulation and on/off configurations.
Kit numbers for direct vent systems available for CBT boilers by HP size.
| Brand | CleaverBrooks |
|---|---|
| Model | CBT |
| Category | Boiler |
| Language | English |