Multi-Appliance Touch Pad Control
PNE2002 Series Control
Page 9
Navi
atin
the Controls
SETUP - SETTING UP OR REVIEWING VARIOUS FUNCTIONS
To view the SETUP options available, press the touch pad
anywhere within the SETUP outline. The available
functions are:
• PGRM – Program setup allows you to create a timed
program to start and stop the product. There are 4
period programs available requiring a minimum of 2 to
be set per day.
For ducted evaporative air conditioning the program
option will only function for 24 hours and then the unit
will stop.
• CLOCK – Setting the time
• REVIEW – Pressing the review button will
automatically step the control through the timer
programs set.
C
HILD LOCK
This function is designed to be a simple mechanism to lock
the control to prevent unnecessary adjustments to the
system. When the lock is engaged there will be no system
functions available. (this is available in either on or off
modes)
• To engage the Child Lock press and hold anywhere
over the numeric display for 4 seconds. A BEEP
followed by a another BEEP will be heard to indicate
the lock is ON.
• To remove the child lock press and hold anywhere over
the numeric display for 4 seconds. A Single BEEP
followed by another single BEEP will be heard to
indicate the lock is OFF.
T
EMPERATURE / TIME TOGGLE
To change the display between temperature and time just
press anywhere in the numeric display. In Evaporative
Cooling mode only the time will be displayed.
Z
ONES – WHERE ZONE MOTORS ARE FITTED
These icons allows zones to be turned ON or OFF. This
function will ONLY be made available by the installer if zone
motors have been fitted to your duct work.