MAN.161 Rev.7 ENG - Use and maintenance manual S15 page
53
of
71
(hydraulic tank capacity: 40 lt)
Grease:
• for boom extension and outriggers:
Interflon Grease LS1/2
Composition: mixture of mineral oils, calcium-lithium complex thick-
ener, additives and Teflon®.
(working field: from -20°C to +120°C)
• for lubricators and bearing:
WHITE STAR NLGI 0 E 2
Composition: mixture of mineral oils and additives.
(working field: from -30°C to +110°C)
• for chains:
Interflon LUBE EP+
Composition: mixture of mineral and vegetable oils, additives and
Teflon®.
Density, 20°C: 0,89 g/cm3
Kinematic viscosity, 20°C (ASTM D2983): 380 mPa.
Before oil replacement, place an oil drip tray in order to avoid the
leakage of oil in the environment.
Do not disperse the exhausted oil or other consumables in the
environment; put them in the appropriate containers and give
them to the authorized collection centers.
8.14
Indications for the demolition of the
MEWP
In case of demolition, the machine must be dis-
mantled completely according to the laws in
force.
The different types of materials must be destined to the respective
authorized centers of collection.
The following material must undergo differentiated disposal therefore placed
in suitable places and containers:
Ferrous materials: carpentries and mechanical components.
Plastic materials: gaskets, straps, and protections.
Electrical materials: windings, controls, electro valves and similar.
Oils and lubricants: hydraulic oil, reducer lubricants, and lubricants
greases.
8.15
Service