MAN.161 Rev.7 ENG - Use and maintenance manual S15 page
49
of
71
Operations
by USER
In case of nega-
tive result of the
Intervention
by
Check the absence of splits, cracks,
rust on the structure of the MEWP
It is strictly
forbidden to use
the MEWP. Con-
tact the Servicing
C.M.C.
Check that the safety devices (emer-
gency buttons, inter-block system for
outriggers-boom) work perfectly
It is strictly
forbidden to use
the MEWP. Con-
tact the Servicing
C.M.C.
Check that the controls, the pilot
lights, the emergency buttons work
perfectly
It is strictly
forbidden to use
the MEWP. Con-
tact the Servicing
C.M.C.
Check the wholeness of the cable
chains
It is strictly
forbidden to use
the MEWP. Con-
tact the Servicing
C.M.C.
Check that the blocking systems
(pins, locknut, etc.) are in perfect con-
dition and efficient
It is strictly
forbidden to use
the MEWP. Con-
tact the Servicing
C.M.C.
Operations
by USER
In case of nega-
tive result of the
Intervention
by
Check the wholeness of the flexible
pipes, of the pipe fitting and the
components of the hydraulic circuit:
check that there is no oil leakage in hy-
draulic circuit
Replacement
USER/
C.M.C.
Check that the electrical contacts are
not slacken
Reset connec-
tions.
USER/
C.M.C.
Check that there is no trace of clashes
on the equipment
It is strictly
forbidden to use
the MEWP. Con-
tact the Servicing.
C.M.C.
8.2
Weekly maintenance
(or every 40 hours)
Operations by
Check the absence of splits, cracks, rust on the MEWP
counter frame (use torches or lamps to inspect the internal
part under the floor).
USER /
C.M.C.
Check the cleanliness of the chassis engine and auxil-
Check the cleanliness of the hydraulic filters. USER /
C.M.C.
8.3
Monthly maintenance
(or every 120 hours)
Operations by
Greasing of pins and movable parts
USER / C.M.C.
Check the tightening of the bolts of the bearing, the
geared motor and the frame