Chapter 3: Operation
98-148232-E To access the terminal from a remote location 32
1. To use an SMS to allow access to the web interface for specific IP addresses, send the
following command:
ATCO <resp_mode> <rsms_pwd> _IREMWEB=1,<ip address>[,<ip address>]
Example: ATCO 2 remote _IREMWEB=1,214.123.189.119
In this example the command specifies no immediate response, only when the global IP
address is sent along (2). The remote SMS password is remote and the IP address
214.123.189.119 can get remote access to the web interface (if two IP addresses are
listed, it is interpreted as a range of IP addresses).
2. The EXPLORER 540 should now return an SMS response with the external IP address of the
terminal.
Example: _IREMWEB:81, GlobalIP:161.30.181.31
81 is the response code for a remote web connection that was set up successfully. It is
followed by the global IP address, which is the IP address to enter in your browser to
access the web interface from the remote device with the IP address you specified in the
command.
3. On the remote computer, open your web browser.
4. In the address bar of your browser, enter the global IP address of the EXPLORER 540
(received in the response above).
You should now be connected to the built-in web interface of the terminal.
To get remote access to the web interface from a trusted IP address (preconfigured)
1. Connect a computer to the EXPLORER 540 and access the web interface locally.
2. Prepare the terminal as described in Remote management on page 85.
3. Make sure your remote computer has access to the Internet.
4. On the remote computer, open your web browser.
5. In the address bar of your browser, enter the IP address of the terminal followed by a colon
and the port number
http://<ip address>:<incoming port>.
<ip address> is the external IP address of the EXPLORER 540. The external IP address can
only be obtained when a data connection (PDP context) is established. If a data
connection is started. you can get the external IP address with the GETINFO SMS
command, see GETINFO: Get information from the EXPLORER 540 on page 27.
<incoming port> is the port you defined in Remote management on page 85 (Incoming
port for web application, default port 80).
Note
Access to the EXPLORER 540 web interface is restricted with a password. See Security
setup on page 34 and Passwords on page 77.
Note
This method requires that you initially have local access to the EXPLORER 540. If not,
use the _IREMWEB command described in the previous section.