ID-FLX Lite & Telecom Global Guide
124
Setpoint group Engine parameters Related FW 2.5.0
Range [units] 0 .. 3000 [RPM]
Default value 0 -
Step 1
Comm object 11125 Related applications
Description
Limit for Speed Request transformation from RPM to % range for ECU engines using % format.
Example:
If ECU is configured, then on one of the measurement screen you can see two lines SpeedReq Abs
and SpeedReq Rel.
In default setting:
0 RPM = 0 %
800 RPM = 33.3 %
2400 RPM = 100 %
Different setting:
800 RPM = 0 %
1200 RPM = 33.3 %
2400 RPM = 100 %
It is possible easily configure own output curve and use it for analog output Speed Request.
0%ofSpeedReq
6 back to List of setpoints
Setpoint group Engine parameters Related FW 2.5.0
Range [units] 0 .. 4000 [RPM]
Default value 2000 -
Step 1
Comm object 11126 Related applications
Description
Limit for Speed Request transformation from RPM to % range for ECU engines using % format.
100%ofSpeedReq
6 back to List of setpoints
Setpoint group Engine parameters Related FW 2.5.0
Range [units] 0 .. 600 [s]
Default value 7 -
Step 1
Comm object 11835 Related applications
Description
Horn time before the conveyor output starts.
Conveyor horn
6 back to List of setpoints

Table of Contents

Other manuals for ComAp InteliDrive Lite

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ComAp InteliDrive Lite and is the answer not in the manual?

ComAp InteliDrive Lite Specifications

General IconGeneral
BrandComAp
ModelInteliDrive Lite
CategoryController
LanguageEnglish

Related product manuals