Table 7.1 Direct cable connection types
Note: It is possible to create multiple controller connection through RS485. Be aware of controller address
collision. Manage address setting for each controller in ControllerAddr (page 103).
Note: ComAp recommends using galvanicaly separated cable.
7.2 Remote connection
7.2.1 Internet connection
ID-Lite controllers can be monitored from PC tools as LiteEdit or InteliMonitor over the Internet using
InteliBridge-NT connected to the controller via IL-NT RS232-485 port, via optional IB-Lite plug-in module or via
IL-NT GPRS for cellular internet network, see Group: Communication settings on page 103.
7.2.2 AirGate connection
ID-Lite controllers can be monitored from PC tools as LiteEdit or InteliMonitor via AirGate. AirGate technology is
for easy plug and play wireless communication. Common SIM card with GPRS service is suitable for this
system. It overcomes problems with special SIM card (fixed and public IP) necessity, with firewalls and difficult
communication settings. For AirGate connection is possible to use IB-NT, IB-Lite or IL-NT GPRS modules. For
setting see Group: Communication settings on page 103.

Table of Contents

Other manuals for ComAp InteliDrive Lite

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ComAp InteliDrive Lite and is the answer not in the manual?

ComAp InteliDrive Lite Specifications

General IconGeneral
BrandComAp
ModelInteliDrive Lite
CategoryController
LanguageEnglish

Related product manuals