M0201AJB Era
™
Medium Power Carrier Access Point Installation Guide
© October 2018 CommScope, Inc. Page 11
Safely Working with Era Hardware
Compliance
1 Notice:Forinstallations,whichhavetocomplywithFCCRFexposurerequirements,theantenna
selectionandinstallationmustbecompletedinawaytoensurecompliancewiththoseFCCrequirements.
DependingontheRFfrequency,ratedoutputpower,antennagain,andthelossbetweentherepeaterand
antenna,theminimumdistanceDtobemaintainedbetweentheantennalocationandhumanbeingsis
calculatedaccordingtothisformula:
where
• P(mW)istheradiatedpowerattheantenna,i.e.themax.ratedrepeateroutputpowerinadditionto
theantennagainminusthelossbetweentherepeaterandtheantenna.
• PD(mW/cm²)istheallowedPowerDensitylimitacc.to47CFR1.1310(B)forgeneralpopulation/
uncontrolledexposureswhichis
– f(MHz)/1500forfrequenciesfrom300MHzto1500MHz
– 1forfrequenciesfrom1500MHzto100,000MHz
RFexposurecompliancemayneedtobeaddressedatthetimeoflicensing,asrequiredbytheresponsible
FCCBureau(s),includingantennaco-locationrequirementsof1.1307(b)(3).
2 Notice:ForinstallationswhichhavetocomplywithEuropeanEN50385exposurecompliance
requirements,thefollowingPowerDensitylimits/guidelines(mW/cm²)accordingtoICNIRParevalid:
• 0.2forfrequenciesfrom10MHzto400MHz
• F(MHz)/2000forfrequenciesfrom400MHzto2GHz
• 1forfrequenciesfrom2GHzto300GHz
3 Notice:Installationofthisequipmentisinfullresponsibilityoftheinstaller,whohasalsothe
responsibility,thatcablesandcouplersarecalculatedintothemaximumgainoftheantennas,sothatthis
value,whichisfiledintheFCCGrantandcanberequestedfromtheFCCdatabase,isnotexceeded.The
industrialboostersareshippedonlyasanakedboosterwithoutanyinstallationdevicesorantennasasit
needsforprofessionalinstallation.
4 Notice:ForinstallationswhichhavetocomplywithFCC/ISEDrequirements:
English:
ThisdevicecomplieswithFCCPart15.Operationissubjecttothefollowingtwoconditions:(1)this
devicemaynotcauseinterference,and(2)thisdevicemustacceptanyinterference,including
interferencethatmaycauseundesiredoperationofthedevice.
ThisdevicecomplieswithHealthCanada'sSafetyCode.TheinstallerofthisdeviceshouldensurethatRF
radiationisnotemittedinexcessoftheHealthCanada'srequirement.Informationcanbeobtainedat
http://www.hc-sc.gc.ca/ewh-semt/pubs/radiation/radio_guide-lignes_direct-eng.php.
Changesormodificationsnotexpresslyapprovedbythepartyresponsibleforcompliancecouldvoidthe
user'sauthoritytooperatetheequipment.
AntennaStmtforISED:
Thisdevicehasbeendesignatedtooperatewiththeantennashavingamaximumgainof9dBi.Antennas
havingagaingreaterthan9dBiareprohibitedforusewiththisdevicewithoutconsentbyISED
regulators.Therequiredantennaimpedanceis50ohms.
Theantenna(s)usedforthistransmittermustbeinstalledtoprovideaseparationdistanceofatleast100
cmfromallpersonsandmustnotbeco-locatedoroperatinginconjunctionwithanyotherantennaor
]/[
][
][
2
4
cmmW
mW
cm
PD
P
D
∗∗
=
π