5. Each Component Function
Users Manual
71
Table 5.22. RESET: Reset Output Modes
Inhibits RESET output when time expires on the WDT.
Allows RESET output when time expires on the WDT.
Note! When time expires on WDT, the alarm-out is output irrelevant
to the settings of the port for controlling event output.
1
RESET output at occurrence of WDT errorsRESET
0
* 4005h: RAS status port
D6 D5 D4 D3 D2 D1 D0D7
WDT
R (Default: XXXXXXX0b)
Figure 5.13. RAS Status Port (4005h)
R : RAS status port
WDT: WDT status
This is the WDT status bit. This bit is
cleared when the WDT stops (read port
4002h).
0 : The WDT is either stopped or
counting.
1 : The time set on the WDT expired.