85
Troubleshootingprocedure:Starterfailure.
Rotation failure of startin
g
motor
Switch on the ignition switch, pressing the horn button
or
p
ush the turn li
g
ht switch
No sound or weak sound output of electric horn and dim
li
g
hts from the turn li
g
ht
Loud sound output from the electric horn and bright lights from
the turn light
Poor ele ctricity of battery or poor
contact of conductor connector on
the battery
Press the starting button and no
joint sound is outputted from the
startin
g
rela
y
Press the starting button and the
joint sound is outputted from the
startin
g
rela
y
Remove the starting relay connector clip from the complete-vehicle
cable, connect the anode and the cathode of the battery to two
leading wires of the starting relay with two wires.
Realize the short circuit between the battery binding post
on the starting relay and the starting motor binding post via
a screw driver or a thick conductor.
The starting motor is not rotated
after the connection and no joint
sound is outputted from the
starting relay.
The starting motor is operational
after the connection.
The starting motor is
inoperational after the
short circuit.
The starting motor is
operational after the
short circuit.
Open circuit or short circuit of
starting relay
Inspect the internal coil of the
electric starting a
nd control
[1] Inspect if the internal contact of the
clutch switch has poor contact
[2] Inspect if the starting button contact
has poor contact
[3] Inspect if the open circuit or short
circuit is made for the internal line of the
electric starting control system
Burnout or damage
of starting relay
contact
Disassemble the starting motor and make the
following inspections:
[1] Inspect if the carbon brush is highly worn.
[2] Inspect if the carbon brush spring is fractured
or is of poor elasticity
[3] Inspect if the armature commutator is hi ghly
worn
[4] Inspect if the commutator coil is in open circuit
or short circuit