Chapter 6. Manage / Configure the Switch
85
#show rate-limit
Ingress Drop Mode: Enable
Rate Control Unit(Kbps): 128
[Rate Control Configuration]
Port Ingress Egress
================================================
1/1 No Limit No Limit
1/2 No Limit No Limit
1/3 No Limit No Limit
1/4 No Limit No Limit
1/5 No Limit No Limit
1/6 No Limit No Limit
1/7 No Limit No Limit
1/8 No Limit No Limit
1/9 No Limit No Limit
1/10 No Limit No Limit
22. show snmp command
This command is used to show SNMP configuration of the switch.
For example,
# show snmp
[SNMP Configuration]
Object ID : 1.3.6.1.4.1.655.100.2.1
System up Time: 4015 (seconds)
System Name :
Location :
Contact name :
Get Community : public
Set Community : private