© 2013 Cummins-Allison Corp.
DOC CORRECT ADJ
(Continued)
To activate the SERIAL-NUMBER, BAR-CODE or MICR-LINE CORRECTION
screens:
1. Press or to select the desired document type.
2. Press
or
to enable or disable the correction screen for the
selected document type.
3. Use
and
to select a THRESHOLD level from 1 to 10. The threshold
setting applies to all denominations and document types.
4. Repeat steps 1 through 3 as needed.
5. When finished, press
to return to the ADJUSTMENT MENU.
SPEED ADJ
(Speed Adjustment)
Prompts the MACHINE SPEED ADJUSTMENT screen shown below.
The default processing speed and maximum ticket processing speed is
1200 BPM (bills per minute or documents per minute). A slower speed
may be selected to process poor-quality documents as needed.
To adjust machine speed:
1. Press a key to select a different processing speed.
2. Press
to return to the ADJUSTMENT MENU.
Machine configuration determines which
processing speeds are available. (For more
information, see Adjustable Processing Speed in