Function
Description
Values
Code
Short name
Alarm air temp. B
Measured temperature for alarm thermostat
U34
U34 Alarm air B
Alarm air temp. C
Measured temperature for alarm thermostat
U92
U92 Alarm air C
High alarm limit
Readout of actual high alarm limit for the tempera-
ture monitoring
y10
--- High al. lim
Low alarm limit
Readout of actual low alarm limit for the temperature
monitoring
y11
--- Low al. lim
S4 Air OFF evap. A
Actual sensor value
u16
u16 S4 air temp.
S4 Air OFF evap. B
Actual sensor value
U76
U76 S4 temp B
S4 Air OFF evap. C
Actual sensor value
U85
U85 S4 temp C
Reset alarms
Command for resetting all alarms, unless they are still
active
0=OFF, 1=ON
x15
--- Reset alarm
High alarm limit 1
Upper alarm limit. The limit value is set in absolute
value. The limit value will be raised with the night o-
set during night operation.
A13
A13 HighLim Air
Low alarm limit 1
Lower alarm limit. The limit value is set in absolute
value
A14
A14 LowLim Air
High alarm limit 2
Upper alarm limit. The limit value is set in absolute
value. The limit value will be raised with the night o-
set during night operation.
A20
A20 HighLim2 Air
Low alarm limit 2
Lower alarm limit. The limit value is set in absolute
value
A21
A21 LowLim2 Air
Alarm delay A
Alarm delay (short alarm delay on air temperature). If
the upper or the lower alarm limit values are excee-
ded, a timer function will commence. The alarm will
not become active until the set time delay has been
passed. The time delay is set in minutes
A03
A03 Alarm delay
Alarm delay pull-
down A
Alarm delay at tempeature pull down conditions
(long alarm delay). This time delay is used during
start-up, during defrost and immediately after a de-
frost. There will be a change-over to the normal time
delay when the temperature has dropped below the
set upper alarm limit.
A12
A12 Pulldown del
Door open alarm
delay
Time delay for door alarm
A04
A04 DoorOpen del
Door restart inj. de-
lay
Start of refrigeration when the door is open. If the
door has been left open, refrigeration will be started
after the set time.
o89
o89 DoorInjStart
Alarm delay DI 1
Time delay for digital input alarm
A27
A27 Al.Delay DI1
Alarm delay DI 2
Time delay for digital input alarm
A28
A28 Al.Delay DI2
© Danfoss | Climate Solutions | 2022.08 BC365022028193en-000201 | 45