Danfoss MCX08M

Danfoss MCX08M
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
REFRIGERATION &
AIR CONDITIONING DIVISION
User manual
MAKING MODERN LIVING POSSIBLE
Danfoss Electronics spa
Air handling Seq.
control algorithm
Software version 2.1
Question and Answer IconNeed help?

Do you have a question about the Danfoss MCX08M and is the answer not in the manual?

Danfoss MCX08M Specifications

General IconGeneral
TypeProgrammable Controller
Input voltage24 V AC/DC
CommunicationRS485, Modbus
Supply voltage24 V AC/DC
Digital inputs8
Analog inputs2
Analog outputs2
Protection classIP20
MountingDIN Rail
OutputRelay, Analog
Output current2 A
Temperature range-20 - 60 °C
Operating temperature-20 - 60 °C

Summary

User Interface and Navigation

Alarms Management

Describes how to view and handle system alarms.

Parameter Access

Provides access to the system's configurable parameters.

Configuring the AHU Software

Configuration Overview

Outlines the main steps for adapting the AHU software to specific applications.

InputOutput Configuration

Lists and describes available analog and digital inputs/outputs for configuration.

Coils Control

Assigning Control Sequences

Defines the function and control sequence for each heating/cooling coil.

Coil Output Management

Sets how coil outputs are managed based on load demand.

Valve Control

Details valve types (ON/OFF, 0/10V, 3-points) and their corresponding outputs.

Step Control

Covers step control for coils, like electric resistances.

Pump Control

Manages pump operation for each coil, including delays and activation parameters.

Cooling Coil Defrost Control

Manages defrost sequences for cooling coils to prevent ice buildup.

Dampers and Energy Recovery Control

External and Mixing Dampers

Describes the control of external and mixing dampers.

Temperature Control Sequences

Damper Control Sequences

Configures sequences for managing dampers and energy recovery units.

Heat and Cool Control Sequences

Details the parameters for heat (HS1, HS2) and cool (CS1) control sequences.

Main Setpoint

Defines main setpoints for heating, cooling, humidity, and economy modes.

Frost Protection

Frost Prevention in OFF

Manages frost prevention when the unit is turned off.

Controlling the Supply Temperature Limits

Supply Temperature Lower Limit

Protects against excessively cold supply air by setting a lower limit.

Supply Temperature Upper Limit

Prevents condensation by setting an upper limit for supply air temperature.

Humidity Control

Humidifier Control

Configures the operation of humidifiers and their pumps.

Dehumidifier Control

Details the control of dehumidification using digital and analog outputs.

Alarms

Parameters

Appendix - Use of the Configurator

Guide to Modifying Application Software

Step-by-step instructions for modifying the AHU application software.