Chapter 4 Operation and display VFD500 high performance vector control frequency inverter user manual
!
4-3Trial run flow chart!
start
Follow the instructions in Chapter 3 to install the inverter and wire it
Make sure the power cable , motor cable and brake unit are connected
correctly
Observe the safety precautions and switch on the power supply
Enter guide mode -GdE-
Set each parameter in turn according to the
guidance of the wizard , set the motor self -
learning mode P 11.10, press the run b utton,
waiting for the complete of self -learning
Press RUNto Run inverter
Press STOP to stop inverter
While monitoring the output frequency
or command frequency ,press
ENTERto modify the target
frequency
End
close loop vector control (VC),Before normal
operation , ensure that the encoder P 10.03 is in
the correct directionIf rotary self -learning is
performed , the encoder orientation can be
automatically recognized and storedIf it is not
executed , it needs to open the loop control to
run the motor and observe whether the encoder
feedback (r10.12) is in the same direction with
the given direction , if no,change as P 10.03
Open control
Y
N
40