EasyManuals Logo

Danfoss VFD500 Series User Manual

Danfoss VFD500 Series
137 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #46 background imageLoading...
Page #46 background image
VFD500 high performance vector control frequency inverter user manual Chapter 5 function code table
P00.06
Source of the
Operation Command
0keypad
1terminal
2communication
Command source: runstopforward
reversejogfast brake stop.etc
If use with DI function, 12Switching run
command to Keypad and 13Switching
run command to Communication,Actuall
effective command source is related with
DI status
0
P00.07
Numeric frequency
setting
00.00Hzmaximum frequency(Set P21.17=1
to change the unit to 1Rpm)
50.00Hz
P00.08
Rotation direction
0Forward
1Reverse
It is only for keypad control to change
running direction by giving frequency
symbol to be reverse)If command by
keypad/terminal /communication,and not
want to achieve reverse running by
giving frequency symbol to be
reverse,need to change P22.13 in stop
mode(see parameter P22.13)
0
P00.09
Reverse control
0enable
1disbale
0
P00.10
Motor option
0motor 1
1motor 2
If use with DI function,16:Switch between
motor 1 and motor 2,Actuall effective
command source is related with DI status
0
P00.11
Special industry
0standard drive
1Reserved
0
r00.18
Power board software
version
 -
-
r00.19
Control board software
version
 -
-
r00.21
SN 1
 -
-
r00.22
SN 2
 -
-
Function
code
Parameter name
Description
Default
Property
Function
code
Parameter name
Description
Default
Property
01Group frequency source selction
43

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VFD500 Series and is the answer not in the manual?

Danfoss VFD500 Series Specifications

General IconGeneral
BrandDanfoss
ModelVFD500 Series
CategoryDC Drives
LanguageEnglish

Related product manuals