VFD500 high performance vector control frequency inverter user manual Chapter 5 function code table
P00.06
Source of the
Operation Command
0:keypad
1:terminal
2:communication
➢
Command source: run、stop、forward、
reverse、jog、fast brake stop.etc
➢ If use with DI function, 12:Switching run
command to Keypad and 13:Switching
run command to Communication,Actuall
effective command source is related with
DI status
0
★
P00.07
Numeric frequency
setting
00.00Hz~maximum frequency(Set P21.17=1
to change the unit to 1Rpm)
50.00Hz
☆
P00.08
Rotation direction
0:Forward
1:Reverse
➢ It is only for keypad control to change
running direction by giving frequency
symbol to be reverse)If command by
keypad/terminal /communication,and not
want to achieve reverse running by
giving frequency symbol to be
reverse,need to change P22.13 in stop
mode(see parameter P22.13)
0
☆
P00.09
Reverse control
0:enable
1:disbale
0
★
P00.10
Motor option
0:motor 1
1:motor 2
If use with DI function,16:Switch between
motor 1 and motor 2,Actuall effective
command source is related with DI status
0
★
P00.11
Special industry
0:standard drive
1:Reserved
0
★
r00.18
Power board software
version
 -
-
●
r00.19
Control board software
version
 -
-
●
r00.21
SN 1
 -
-
●
r00.22
SN 2
 -
-
●
Function
code
Parameter name
Description
Default
Property
Function
code
Parameter name
Description
Default
Property
01Group frequency source selction