Motor
Abbreviation/Definition Description
f
M,N
The rated motor frequency (nameplate data)
I
M,N
The rated motor current (nameplate data)
I
0
Idle current
n
M,N
The rated motor speed (nameplate data)
n
slip
Slip in motor speed
P
M,N
The rated power delivered by the motor (nameplate data)
P
0
Power losses at idle state
R
Fe
Iron loss resistance
R
2
Rotor resistance
R
S
Stator resistance
T
M,N
The rated torque (motor)
U
M,N
The rated motor voltage (nameplate data)
X
1σ
Stator Leakage Reactance
X
2σ
Rotor Leakage Reactance
X
h
Main Reactance
References
Abbreviation/Definition Description
Analog ref. A signal transmitted to input 53, 54 or 60. Can be voltage or current
Binary ref. A signal transmitted to the serial communication port
Ref
MAX
The maximum value which the reference signal may have. Set in parameter 205
Miscellaneous
Abbreviation/Definition Description
Analog inputs The analog inputs can be used for controlling various functions of the frequency converter. There are
two types of analog inputs:
Current input and voltage input
Analog outputs There are two analog current outputs
AWG Means American Wire Gauge, ie. the American measuring unit for cable cross-section
Brake resistor The brake resistor is a module capable of absorbing the brake power that is generated in regenerative
braking. This regenerative braking power increases the intermediate circuit voltage and a brake chopper
ensures that the power is transmitted to the brake resistor
ccw Counter Clockwise rotation
CL Closed Loop
Coast (motor) The motor is free running to stop
CP Constant power
CT characteristics Constant torque characteristics, used for all applications, such as conveyor belts and cranes.
cw Clockwise rotation
DC Link Intermediate circuit in the frequency converter
Digital inputs The digital inputs can be used for controlling various functions of the frequency converter
Digital outputs There are four digital outputs, two of which activate relay switches.
DSP Digital Signal Processing. The FLUX processor is defined as a DSP
MG.55.A6.02 - VLT is a registered Danfoss trademark
6

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT 5000 FLUX and is the answer not in the manual?

Danfoss VLT 5000 FLUX Specifications

General IconGeneral
BrandDanfoss
ModelVLT 5000 FLUX
CategoryDC Drives
LanguageEnglish

Related product manuals