DK-45 Kullanım Kılavuzu V1.0 (22.09.2016)
- 47 -
ICON and No:
DESCRIPTION
ADJUSTMENT LIMITS
Factory
Set
F.01
MAX STRTS PER H :
Maximum number of
starts allowed in one
hour
6 ... 240
20
F.02
STP.SRVC.RQUEST :
Service safety
selection
0: Warning only on service request
1:Operates as explained in chapter 5.1
0
F.03
MOTOR HOUR CAL :
Motor hours
calculation method
0: Constant coefficient
1: Variable coefficient
Please see chapter 6.3 for details.
0
ICON and No:
DESCRIPTION
ADJUSTMENT LIMITS
Factory
Set
G.01
LEVL 1 PASSWORD :
Low level password
0 ... 999
1
G.02
LEVL 2 PASSWORD :
High level password
0 ... 999
2
10.2.6. MOTOR PARAMETERS
10.2.7. PASSWORD CHANGING