154
Matrix 120
Chapter 10
Technical Features
Electrical Features
Power
Supply Voltage
5 to 30 Vdc
(10 to 30 Vdc with CBX)
Consumption 0.4 to 0.1 A
Communication Interfaces
Main: RS232, RS422 Full-duplex 2400 to 115200 bit/s
USB USB 2.0 Hi-Speed
Ethernet (Built-in)
supported application protocols
10/100 Mbit/s
TCP/IP, EtherNet/IP, Modbus TCP, PROFINET-IO
Fieldbus CBX500 with HMS Host Interface Modules
Inputs
Input 1(External Trigger) and Input 2
short circuit protected
(opto-isolated and polarity insensitive when connected
through CBX)
Max. Voltage 30 Vdc
Max. Input Current 3.5 mA (24 mA max when connected through CBX)
Outputs
a
a. when connected to the CBX connection boxes the electrical features for Output 1 and 2 become the following:
Opto-isolated; V
CE
= 30 Vdc max.; I
CE
= 40 mA continuous max.; 130 mA pulsed max.;
V
CE saturation
= 1 Vdc max. @ 10 mA; P
D
= 90 mW Max. @ 50 °C ambient temp.
Output 1 and 2
NPN or PNP short circuit protected
(opto-isolated and polarity sensitive when connected
through CBX)
V
OUT high
(I
LOAD
= 100 mA) Max.
28.3 Vdc (when using 30 Vdc power supply)
V
OUT low
(I
LOAD
= 100 mA) Max.
1.7 Vdc
I
LOAD
Max.
145 mA