EasyManua.ls Logo

Datalogic Matrix 120 - Technical Features; Electrical Features

Datalogic Matrix 120
188 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
154
Matrix 120
Chapter 10
Technical Features
Electrical Features
Power
Supply Voltage
5 to 30 Vdc
(10 to 30 Vdc with CBX)
Consumption 0.4 to 0.1 A
Communication Interfaces
Main: RS232, RS422 Full-duplex 2400 to 115200 bit/s
USB USB 2.0 Hi-Speed
Ethernet (Built-in)
supported application protocols
10/100 Mbit/s
TCP/IP, EtherNet/IP, Modbus TCP, PROFINET-IO
Fieldbus CBX500 with HMS Host Interface Modules
Inputs
Input 1(External Trigger) and Input 2
short circuit protected
(opto-isolated and polarity insensitive when connected
through CBX)
Max. Voltage 30 Vdc
Max. Input Current 3.5 mA (24 mA max when connected through CBX)
Outputs
a
a. when connected to the CBX connection boxes the electrical features for Output 1 and 2 become the following:
Opto-isolated; V
CE
= 30 Vdc max.; I
CE
= 40 mA continuous max.; 130 mA pulsed max.;
V
CE saturation
= 1 Vdc max. @ 10 mA; P
D
= 90 mW Max. @ 50 °C ambient temp.
Output 1 and 2
NPN or PNP short circuit protected
(opto-isolated and polarity sensitive when connected
through CBX)
V
OUT high
(I
LOAD
= 100 mA) Max.
28.3 Vdc (when using 30 Vdc power supply)
V
OUT low
(I
LOAD
= 100 mA) Max.
1.7 Vdc
I
LOAD
Max.
145 mA