Outputs
Product Reference Guide 65
By default, Output 1 is associated with the No Read event, which activates when
the code(s) signaled by the external trigger are not decoded, and Output 2 is
associated with the Good Read event, which activates when all the selected codes
are correctly decoded.
The output signals are fully programmable being determined by the configured
Activation/Deactivation events, Deactivation Timeout or a combination of the
two. Refer to the DL.CODE parameters Help On Line for further details.
Output 1 and 2 Connections Using Matrix 120 Power
Figure 46 - PNP/Open Emitter Output Using Matrix 120 Power
Figure 47 - NPN/Open Collector Output Using Matrix 120 Power
CAUTION
Power from the Vdc/GND spring clamps is available directly to the Output Device on
the +V/-V spring clamps, and does not pass through the Power Switch (ON/OFF)
inside the CBX. Disconnect the power supply when working inside the CBX.