Inputs
Product Reference Guide 161
Inputs
There are two non opto-isolated inputs available on the M12 17-pin connector
of the reader: Input 1 (External Trigger) and Input 2, a generic input.
The electrical features of both inputs are:
* The OFF state is guaranteed even if the input is floating.
The relative pins on the M12 17-pin connector are:
INPUT
V
IN
Min. V
IN
Max. I
IN
Max
.
NPN
OFF* 4 V 30 V 0 mA
ON 0 V 2.5 V 0.3 mA
PNP
OFF* 0 V 2.5 V 0 mA
ON 4 V 30 V 3.5 mA
Input Pinout
Pin Name Description
6 IN1 External Trigger (referenced to GND)
13 IN2 Input 2 (referenced to GND)
2 GND Power Supply input voltage -
NOTE
These inputs become opto-isolated when connected to the CAB-1011 accessory cable
and acquire the electrical features described in "
Inputs" on page 58.