Loading...
Optical Features
Product Reference Guide 155
Optical Features
Environmental Features
WVGA MP
Image Format 752x480 1280x960
Frame Rate 57 frames/sec. 36 frames/sec.
Focus Range
a
Factory calibrated positions (mm)
a. three factory calibrated positions; continuous focus range for fine tuning.
45 - 70 - 125 45 - 80 - 125
Image Sensor CMOS sensor with Global Shutter
Pitch 35°
Tilt 0° - 360°(within vertical FOV)
LED Safety to EN 62471
Laser Safety (Aiming source) IEC60825-1 2007
Lighting System Internal Illuminator
Aiming System Laser Indicator
Operating Temperature
a
a. high ambient temperature applications should use metal mounting bracket for heat dissipation.
-0 to 45 C (32 to 113 °F)
Storage Temperature -20 to 70 C (-4 to 158 °F)
Max. Humidity 90% non condensing
Vibration Resistance
EN 60068-2-6
14 mm @ 2 to 10 Hz; 1.5 mm @ 13 to 55 Hz;
2 g @ 70 to 500 Hz; 2 hours on each axis
Bump Resistance
EN 60068-2-29
30g; 6 ms;
5000 shocks on each axis
Shock Resistance
EN 60068-2-27
30g; 11 ms;
3 shocks on each axis
Protection Class
EN 60529
IP65
Sulfur Gas Test
DIN EN 60068-2-43
Passed

Table of Contents