Fieldbus Connection
Product Reference Guide 71
Fieldbus Connection
In this layout a single reader functions as a Slave node on a Fieldbus network.
The data is transmitted to the Host through an accessory Fieldbus interface
board installed inside the CBX500 connection box (i.e. BM300 Profibus or BM400
DeviceNet).
Other I/O devices connected to the CBX can be controlled from the Filedbus Host
through the Matrix reader.
When One Shot or Phase Mode operating mode is used, the reader can be acti-
vated by an External Trigger (photoelectric sensor) when the object enters its
reading zone.
Figure 53 - Fieldbus Interface Point-to-Point Layout
CAUTION
Matrix 120 readers do not have Auxiliary Serial interfaces. Therefore, neither data
monitoring nor device configuration ca be performed through this interface.
Once the Matrix 120 device is configured in DL.CODE for HMS Fieldbus communica-
tion, the Main Serial channel is no longer available.
Therefore, it is recommended to make these configurations when connected to
DL.CODE through either the Ethernet interface (using CAB-ETH-Mxx) or the USB inter-
face (using CAB-1021).
Fieldbus Host
Matrix 120
CBX500 with
Fieldbus Interface (Profibus, DeviceNet, etc.)
Other I/O devices
External Trigger (for One Shot or Phase Mode)
10-30 Vdc Power
CAB-1011
Host Interface Module (Fieldbus)
NOTE
Matrix 120 Ethernet models support Ethernet/IP, Modbus TCP and PROFINET-IO
Fieldbus interfaces without the use of external Fieldbus modules. See Ethernet Con-
nection.