Rapid Configuration
8
Matrix 120
Reset Reader to Factory Default Environment (Optional)
If it ever becomes necessary to reset the reader’s Environment parameters to
their factory default values, you can perform this procedure by holding the X-
PRESS push button pressed while powering up the reader. You must keep the X-
PRESS push button pressed until all LEDs blink simultaneously for about 3
seconds. Release and re-press the button during this LED blinking sequence.
All the device Environment parameters are reset including the default IP Address.
The Matrix 120 emits 3 high pitched beeps and after a few seconds enters run
mode.
Any previously saved configurations on the device will remain in memory, but
the Default configuration is set as the startup configuration.
NOTE
The Grade A Barcode Test Chart cannot be used to set the Code 128 symbology (even
though the reader successfully reads the code). Use the application specific code if
you need to set this symbology.
NOTE
When using X-PRESS or the BM150 menu to perform Auto-Learn, only a single code
can be configured (successive Learns will substitute the current code). To configure
multiple codes, use the DL.CODE Auto-Learn procedure.
NOTE
You can always exit from any X-PRESS function at any time by pressing the X-PRESS
push button once. After a short delay the procedure is canceled.
NOTE
If you have used this procedure to configure Matrix 120, go to step 6.
NOTE
If you release the button while the LEDs are all on continuously (after the blinking
phase), the reader will enter the Loader program sequence and the LEDs will begin to
cycle through various patterns. Just cycle power to return to run mode.