CBX Electrical Connections
64
Matrix 120
Figure 45 - NPN Input 2 Using External Power
Outputs
Three general purpose outputs are available and their meaning can be defined
by the user. They are typically used either to signal the data collection result or
to control an external lighting system.
The electrical features of the outputs are the following:
CAUTION
When Outputs 1 and 2 are connected through the CBX connection box, they become
opto-isolated and polarity sensitive and acquire the electrical characteristics listed
below. To function correctly, they require setting the Output Line Type configuration
parameters to NPN for the respective output. The hardware connection to the CBX
can be either NPN or PNP.
CBX100/500 Description
+V Power Source - Outputs
O1+ Output 1 + opto-isolated and polarity sensitive
O1- Output 1 - opto-isolated and polarity sensitive
O2+ Output 2 + opto-isolated and polarity sensitive
O2- Output 2 - opto-isolated and polarity sensitive
-V Power Reference - Outputs
Outputs 1 and 2
V
CE
= 30 Vdc max.
I
CE
= 40 mA continuous max.; 130 mA pulsed max.
V
CE saturation
= 1 Vdc max. @ 10 mA
P
D
= 90 mW Max. @ 50 °C ambient temp.