Rapid Configuration
4
Matrix 120
CBX100/CBX500 Pinout for Matrix 120
The table below gives the pinout of the CBX100/CBX500 terminal block
connectors. Use this pinout only when the Matrix 120 reader is connected to the
CBX100/CBX500 by means of the CAB-1011 accessory cable:
CBX100/500 Terminal Block Connectors
Input Power Outputs
Vdc Power Supply Input Voltage + +V Power Source - Outputs
GND Power Supply Input Voltage - -V Power Reference - Outputs
Earth Protection Earth Ground O1+ Output 1+
O1- Output 1-
Inputs
02+ Output 2+
+V Power Source - External Trigger O2- Output 2-
I1A External Trigger A (polarity insensitive)
O3A Output 3 (CBX500 only)
I1B External Trigger B (polarity insensitive)
-V Power Reference - External Trigger
Auxiliary Interface
+V Power Source - Inputs
Matrix 120 has no Auxiliary InterfaceI1A Input 2 A (polarity insensitive)
I2B Input 2 B (polarity insensitive)
-V Power Reference - Inputs
ID-NET™
Shield
Matrix 120 has no ID-NET Interface
Cable shield connected to chassis and 17-pin con-
nector shell
Main Interface
RS232 RS422 Full-Duplex
TX TX+
RX
a
RX+
-
a
TX-
- RX-
SGND SGND
a. Do not leave floating, see RS232 Interface for connection details
CAUTION
Do not connect GND and SGND to different (external) ground references. GND and
SGND are internally connected through filtering circuitry, which can be permanently
damaged if subjected to voltage drops over 0.8 Vdc.