54
Matrix 120
Chapter 4
CBX Electrical Connections
All Matrix 120 models can be connected to a CBX connection box through the
CAB-1011 accessory cable. Th
is accessory cable terminates in an M12 17-pin
connector on the Matrix 120 side and in a 25-pin male D-sub connector on the
CBX side.
We recommend making system connections through one of the CBX connection
boxes since they offer the advantages of easy connection, easy device
replacement, opto-isolated inputs (External Trigger and Input 2) and outputs
(Outputs 1 and 2), and filtered reference signals.
The table below gives the pinout of the CBX100/500 terminal block connectors.
Use this pinout when the Matrix 120 reader is connected by means of the
CBX100/500:
CAUTION
Do not use CAB-DSxx-S accessory cables with Matrix 120.
NOTE
If you require direct wiring to the reader the connections are the same as shown in
Appendix A.
Group Label Description
Input Power Vdc Power Supply Input Voltage +
GND Power Supply Input Voltage -
Earth Protection Earth Ground
Inputs +V Power Source - External Trigger
I1A External Trigger A (polarity insensitive)
I1B External Trigger B (polarity insensitive)
-V Power Reference - External Trigger
+V Power Source - Inputs
I2A Input 2 A (polarity insensitive)
I2B Input 2 B (polarity insensitive)
-V Power Reference - Inputs