Interface Related Features
4-26 QuickScan
®
QS6500/QS6500 BT
IBM
IBM Transmit Labels in Code 39 Format
This feature enables/disables imager's ability to set a symbology
identifier for a specified label to Code 39 before transmitting
that label data to an IBM host. This applies to: Code 128, Coda-
bar, and Code 93 for IBM USB; Code 128, Codabar, and Code
93 for IBM Port 5B; and Codabar and Code 93 for IBM Port
9B.
START
STATE BARCODE
Disable
Convert to
Code 39
Enable Convert
to Code 39
END