EasyManua.ls Logo

Dell PowerEdge C6220 - Cable Routing for LSI 9265-8 I Card (1 U Node)

Dell PowerEdge C6220
316 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installing System Components | 169
10 Replace the four screws that secure the LSI 9265-8i card assembly.
11 Install the system-board assembly. See "Installing a System-Board
Assembly" on page 143.
Cable Routing for LSI 9265-8i Card (1U Node)
1 Connect the mini-SAS cable to the LSI 9265-8i card, and connect the
other end of the cable to the corresponding connector on the system
board.
2 Connect the mini-SAS&SGPIO cable to the LSI 9265-8i card, and
connect the other end of the cable to the corresponding connectors on
the system board. Ensure the cables should go through the cable clip
ring. See Figure 3-24.
3 Connect the RAID battery cable to the BBU interposer card on the LSI
9265-8i card, and connect the other end of the cable to the
corresponding connector on the RAID battery.
NOTE: When connecting the RAID battery cable, the BBU interposer card
should be installed on the LSI 9265-8i card. The BBU interposer card in the
figure below is just for you reference.

Table of Contents