Installing System Components | 175 
 
 
Installing the LSI 9265-8i Card for 2U Node 
CAUTION: Many repairs may only be done by a certified service technician. You 
should only perform troubleshooting and simple repairs as authorized in your 
product documentation, or as directed by the online or telephone service and 
support team. Damage due to servicing that is not authorized by Dell is not 
covered by your warranty. Read and follow the safety instructions that came with 
the product. 
CAUTION: Expansion cards can only be installed in the slots on the expansion-
card riser. Do not attempt to install expansion cards directly into the riser 
connector on the system board. 
1  Unpack the LSI 9265-8i card and prepare it for installation. For 
instructions, see the documentation accompanying the card. 
2  Remove the system-board assembly. See “Removing a System-Board 
Assembly" on page 142. 
3  Connect the RAID battery cable to the BBU interposer card. See 
Figure 3-28. 
4  Remove the screw securing the filler bracket. Grasp the filler bracket by 
its edges, and carefully remove it from the riser card. 
NOTE: Keep this bracket in case you need to remove the expansion card. 
Filler brackets must be installed over empty expansion-cards slots to 
maintain FCC certification of the system. The brackets also keep dust and 
dirt out of the system and aid in proper cooling and airflow inside the 
system. 
5  Connect the mini-SAS/SGPIO cables to the LSI 9265-8i card assembly. 
See Figure 3-28. 
6  Holding the card by its edges, position the card so that the card-edge 
connector aligns with the riser card. 
7  Insert the card-edge connector firmly into the riser card until the card 
is fully seated. 
8  Install the expansion slot lock cover by securing the three screws. 
9  Place the LSI 9265-8i card assembly into the system-board assembly. 
10  Replace the four screws that secure the LSI 9265-8i card assembly.