Loading...
Figure 54. Configuration 1: 8 x 2.5-inch NVMe RAID fPERC11
NOTE:
Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse
sequential order.
Table 66. Configuration 1: 8 x 2.5-inch NVMe RAID fPERC11
Order From To
1. SIG_PWR_1 (system board power
connector)
BP_PWR_1 (Front backplane power connector)
2. SL11_CPU2_PB6 (signal
connector on system board)
CTRL_DST_PA1 (fPERC input connector)
3. CTRL_SRC_PA1 (fPERC
controller connector)
BP_DST_PA1 (backplane signal connector) and BP_DST_PB1
(backplane signal connector)
4. CTRL_SRC_PB1 (fPERC
controller connector)
BP_DST_PA2 (backplane signal connector) and BP_DST_PB2
(backplane signal connector)
Installing and removing system components 91