Chapter 7 Servo Parameters|ASDA-B Series
Revision January, 2009 7-19
7.3 Detailed Parameter Listings
Group 0: P0-xx Monitor Parameters
P0 - 00
VER Firmware Version Communication Addr.: 0000H
Default: Factory setting Related Section: N/A
Applicable Control Mode: P/S/T
Unit: N/A
Range: N/A
P0 - 01
ALE Drive Fault Code Communication Addr.: 0001H
Default: Factory setting Related Section:
Applicable Control Mode: P/S/T Chapter 10
Unit: N/A
Range: 1 ~ 20
Settings:
: Overcurrent (Note 1)
: Overvoltage (Note 2)
: Undervoltage (Note 2)
: Z Pulse shift (Note 3)
: Regeneration error (Note 1)
: Overload (Note 1)
: Overspeed (Note 1)
: Abnormal pulse control command (Note 1)
: Excessive deviation (Note 1)
: Serial communication error (Note 2)
: Encoder error (Position detector fault) (Note 3)
: Adjustment error (Note 1)
: Emergency stop (Note 2)
: Reverse (CWL) limit error (Note 2)
: Forward (CCWL) limit error (Note 2)
: IGBT temperature error (Note 2)
: Memory error (Note 4)
: Serial communication time out (Note 2)
: Motor type error (Note 2)
: Input power phase loss (Note 2)