P8 - 00
KVER Keypad Firmware Version Communication Addr.: 0800H
Default: Factory setting Related Section: N/A
Applicable Control Mode: P/S/T
Unit: N/A
Range: N/A
P8 - 01 KFUN Keypad Communication and Reset Setting Communication Addr.: 0801H
Default: 1 Related Section: N/A
Applicable Control Mode: P/S/T
Unit: N/A
Range: 0 ~ 011
Settings:
ASD-PU-01A
ASD-PU-01B
Communication Method Settings:
0: If 0 is set, it indicates the keypad is the slave side during communication. 0 must be set
when communicating with PC, or there will be a communication fault.