Chapter 7 Servo Parameters|ASDA-B Series
Revision January, 2009 7-31
P1 - 26
Reserved Communication Addr.: 011AH
P1 - 27
Reserved Communication Addr.: 011BH
P1 - 28
Reserved Communication Addr.: 011CH
P1 - 29
Reserved Communication Addr.: 011DH
P1 - 30
Reserved Communication Addr.: 011EH
P1 - 31
Reserved Communication Addr.: 011FH
P1 - 32
LSTP Motor Stop Mode Selection Communication Addr.: 0120H
Default: 0 Related Section: N/A
Applicable Control Mode: P/S/T
Unit: N/A
Range: 0 ~ 11
Settings: This parameter is used to select servo motor stop mode.
ASD-PU-01A ASD-PU-01B
Fault Stop Function Settings:
When a fault occurs (except for CWL, CCWL, EMGS and serial communication error), it is
used to set servo motor stop mode.
0: Stop instantly
1: Decelerate to stop
Dynamic Brake Activation Settings:
When a fault occurs (except for CWL, CCWL, EMGS and serial communication error), the
servo drive will turn on (Servo On) and then off (Servo Off) automatically.
0: Use dynamic brake when Servo Off (the servo drive is disabled).
1: Allow servo motor to coast to stop when Servo Off (the servo drive is disabled).