Chapter 8 MODBUS Communications|ASDA-B Series
Revision January 2009 8-7
0307H
Communication
Response Delay
Time
Default: 0
Range: 0~255
This parameter is used to delay the communication time that servo drive respond to host controller
(external controller)
When the communication address is set to 255, the communication response delay time will be 0 (zero)
no matter what the setting value of P3-07 is.