Chapter 2 Devices   
2-13 
SM  Function 
CPU5X0-RS2 
CPU5X0-EN 
OFF
 
ON 
STOP
 
RUN 
RUN 
 
STOP
Attribute 
Default 
SM108 
The receiving of data through COM1 is 
complete. 
○  ×  ○  ○  ×  –  –  –  R/W
OFF
SM109 
The receiving of data through COM2 is 
complete. 
○  ×  ○  ×  ○  –  –  –  R/W
OFF
All non-latched areas are cleared. 
All latched areas are cleared. 
*SM209 
The communication protocol of COM1 changes 
(in accordance with SM210, SR201, SR209, 
○  ○ 
○  ○  ○ 
OFF
–  –  R/W
OFF
*SM210 
Choice made by COM1 between the ASCII 
mode and the RTU mode 
○  ○ 
○  ○  ○ 
OFF
–  –  R/W
OFF
*SM211 
The communication protocol of COM2 changes 
(in accordance with SM212, SR202, SR212, 
○  × 
○  ×  ○ 
OFF
–  –  R/W
OFF
*SM212 
Choice made by COM2 between the ASCII 
mode and the RTU mode 
○  × 
○  ×  × 
OFF
–  –  R/W
OFF
SM220 
Calibrating the real-time clock within ±30 
seconds 
○  ○ 
○  ○  ○ 
OFF
OFF  –  R/W
OFF
*SM400  The flag is always ON when CPU runs.  ○  ○ 
○  ○  ○ 
ON  ON  ON  R  ON 
*SM401  The flag is always OFF when CPU runs.  ○  ○ 
○  ○  ○ 
OFF
OFF  OFF  R  OFF
*SM402  The flag is ON only at the first scan.  ○  ○ 
○  ○  ○ 
OFF
ON  OFF  R  OFF
*SM403  The flag is OFF only at the first scan.  ○  ○ 
○  ○  ○ 
ON  OFF  ON  R  ON 
*SM404 
10 millisecond clock pulse during which the 
pulse is ON for 5 milliseconds and is OFF for 5 
○  ○ 
○  ○  ○ 
OFF
–  –  R  OFF
*SM405 
100 millisecond clock pulse during which the 
pulse is ON for 50 milliseconds and is OFF for 
○  ○ 
○  ○  ○ 
OFF
–  –  R  OFF
*SM406 
200 millisecond clock pulse during which the 
pulse is ON for 100 milliseconds and is OFF for 
100 milliseconds 
○  ○ 
○  ○  ○ 
OFF
–  –  R  OFF
*SM407 
One second clock pulse during which the pulse 
is ON for 500 milliseconds and is OFF for 500 
○  ○ 
○  ○  ○ 
OFF
–  –  R  OFF
*SM408 
Two second clock pulse during which the pulse 
is ON for one second and is OFF for one 
○  ○ 
○  ○  ○ 
OFF
–  –  R  OFF
*SM409 
2n second clock pulse during which the pulse is 
ON for n seconds and is OFF for n seconds   
The interval n is specified by SR409.   
○  ○ 
○  ○  ○ 
OFF
–  –  R  OFF
*SM410 
2n millisecond clock pulse during which the 
pulse is ON for n milliseconds and is OFF for n 
milliseconds   
The interval n is specified by SR410. 
○  ○ 
○  ○  ○ 
OFF
–  –  R  OFF
*SM418 
Port 2 connection status of backplane 1 (main 
backplane) 
×  ×  ○  ○  ○ 
OFF
–  –  R  OFF
*SM420 
Port 2 connection status of backplane 2 (1
st
 
redundant extension backplane)   
×  ×  ○  ○  ○ 
OFF
–  –  R  OFF