151
BHT-1600 Handy Terminal User Manual
Transmit Check Digit
Decide whether to include the check digit in the data to
transmit.
“Verify Check Digit” must be enabled.
Enable
Code 11 Disable
Code 11 Switch to enable Code 11 decoding. Disable
Check Digit Option Sets whether to
verify check digits according to the
selected option. If the check digits are incorrect, the
barcode will not be accepted.
Disable
One Check Digit
Two Check Digits
Disable
Transmit Check Digit Selects whether to include check digits in the transmitted
data.
“Check Digit Option” must be enabled.
Disable
Length option Sets the length of the Code 11 symbols to decode.
One Fixed length (Length 1)
Two Fixed lengths (Length 1>Length 2)
Max / Min Length (range: 0-55; Length 1<Length 2)
Any Length
Max / Min
Length
(4-55)
Code 39 Enable
Code 39 Switch to enable Code 39 decoding. Enable
Trioptic Code 39 Selects whether to decode Trioptic Code 39.
Trioptic
Code 39 is a variant of Code 39 used in the
marking of computer tape cartridges. It always
contains six characters.
Disable
Convert to Code 32
Selects whether to convert decoded data to Italian
Pharmacode.
Disable
Code 32 Prefix Prefix character “A” to Code 32 barcodes.
“Convert to Code 32” must be enabled for this to
function properly.
Disable