Log File
View AutoPoll Log
When the AutoPoll program calls loggers, it creates a text file that contains a summary of all of the
calls made called the AutoPoll Log. An excerpt example of the Log is shown below:
At the end of each call, a dashed line is added to the bottom of the file to separate calling sessions.
The file created shows the status of each call (and attempted call) made to the logger(s) in the
Logger List and includes changes made to the logger clock if the Set Logger Clock flag has been
checked in the Logger List. At the end of the session, a summary of the calls attempted and failed
will be shown. If the software took three attempts to contact a logger and was successful on the
third try, the summary would still show 1 Call Attempted - 0 Calls Failed.
The file created is labeled autopoll.log and is automatically saved to whatever folder contains the
ELOG application program (typically C:\Users\UserName\Documents\DENT\ELOG\Data). The folder
where the file is saved may not be changed except by moving the ELOG application too.
- DENT Instruments -
AutoPoll Event Log File
Connecting to logger ELITE on 04/10/14 at 10:54:31
Direct connection to logger ELITE completed
Setting clock from 10:54:36 04/10/14 to 10:54:38 04/10/14 for logger ELITE
Task complete for call to logger ELITE
Downloading data for logger ELITE
Download of data from logger ELITE completed. Appended to file ELITE-01.elog
All session calls completed - 1 Calls Attempted - 0 Calls Failed
----------------------------------------
Connecting to logger ELITE on 04/10/14 at 11:08:01
Direct connection to logger ELITE completed
Setting clock from 11:08:07 04/10/14 to 11:08:08 04/10/14 for logger ELITE
Task complete for call to logger ELITE
Downloading data for logger ELITE
Download of data from logger ELITE completed. Appended to file ELITE-01.elog
All session calls completed - 2 Calls Attempted - 0 Calls Failed
w ww. . com
information@itm.com1.800.561.8187

Table of Contents

Other manuals for DENT Instruments ELITEpro XC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DENT Instruments ELITEpro XC and is the answer not in the manual?

DENT Instruments ELITEpro XC Specifications

General IconGeneral
BrandDENT Instruments
ModelELITEpro XC
CategoryData Loggers
LanguageEnglish