1. Navigate to “Wheel circumference” as described in 6.4.1 Configuring
settings in the main menu Page EN-54.
You can pick values between:
» 1,510 mm to 2,330 mm
2. Use the
/ buttons to select the option required. The option selected
is highlighted.
3. Conrmingthewheelcircumferencewith
returns you to sub-level 2.
6.4.3.14 Light reserve
Path: Settings | Device settings | Drive | Light reserve
When enabled, the Light reserve function keeps back part of the battery
power for long-term light function. Light reserve is retained for two hours
once assist power is no longer being provided. This function is set as
standard and can be disabled.
1. Navigate to “Light reserve” as described in 6.4.1 Configuring
settings in the main menu Page EN-54.
2. Use the
/ buttons to select “Yes” or
“No”. The option selected is highlighted.
3. Conrmingwith
returns you to sub-level
2.
Light reserve is enabled
0.0
OFF
11:18
km/h
Trip
0.0 km
140km
WARNING
We recommend keeping the light reserve switched on. Otherwise the
lights and the Impulse Evo / Impulse Evo Next system go out at the
same time. If you are out and about in poor light (in fog, rain, early
morning, late evening), you run the risk of not being seen, and as a
result of a serious accident.
6.4.3.15 Shift sensor
Path: Settings | Device settings | Drive | Shift sensor
The shift sensor detects gear changes and interrupts the motor assist for
a fraction of a second (ms = milliseconds). This enables smoother and
quicker gear changes especially with a hub gear. This makes the shift
process more gentle for the pedelec. The higher the value selected, the
longer the interruption to the motor assist and the more time the gear has
to change.
1. Navigate to “Shift sensor” as described in 6.4.1 Configuring settings
in the main menu Page EN-54.
You can choose between:
OFF 50 ms 100 ms 150 ms 200 ms 250 ms 300 ms
Short interruption
Long interruption
2. Use the
/ buttons to select the desired option. The option selected
is highlighted.
3. Conrmingwith