HI, MI, WI-700 service manual - 2 - component parts
2-44 Issue 9 04/2020
Labeller board
Notes:
The IP address is always in the range 192.168.0.xx The xx being which labeller it will be fitted into
(e.g.-labeller 1 has 1, labeller 2 has 2.
The last IP segment is set with the rotary switch on the board. The board is pre-set with 192.168.0.
The rotary switch then sets the labeller number.
J5 label gap sensor jumpers This jumper adjusts the sensor reading value of the gap sensor for
more detail on this refer to gap sensor section. On Signature labellers, an additional sensor I/F board
is fitted for sensor adjustment - see following page, therefore adjustment of this jumper is not
normally required.
(Note: the second set of jumpers, J6 are not used).
There are three connections on the board to allow software updates onto the board. This process
can also be carried out within the machine software (service settings) via Ethernet download
Take up motor
torque setting.
Label feed
button and
red/green
LEDs
For software
programming
(print side) -
also see note
Gap sensor.
8pin connector
J5 – label
gap sen-
sor value
adjust –
see note
below
For software
programming
- also see
note
Labeller IP
address setting.
See note below
For software
programming
(comms
side) - also
see note
Ethernet
comms from
console.
Thermal head
ribbon. 26pin
connector
Dip switches -
not normally
required
Power reset
button
Thermal
head power
Power from
labeller PSUs
Stepper
motor
connection
Solenoid
valves/ fans /
take-up
motor

Table of Contents

Related product manuals