AT commands I/O line passing commands
Digi XBee3® 802.15.4 RF Module User Guide
122
T9 command
Specifies how long pin D9 command holds a given value before it reverts to configured value. If set to
0, there is no timeout.
Parameter range
0 - 0xFF
Default
0
Q0 command
Specifies how long pin P0 holds a given value before it reverts to configured value. If set to 0, there is
no timeout.
Parameter range
0 - 0xFF
Default
0
Q1 command
Specifies how long pin P1 holds a given value before it reverts to configured value. If set to 0, there is
no timeout.
Parameter range
0 - 0xFF
Default
0
Q2 command
Specifies how long pin P2 holds a given value before it reverts to configured value. If set to 0, there is
no timeout.
Parameter range
0 - 0xFF
Default
0
PT (PWM Output Timeout)
Specifies how long both PWM outputs (P0, P1) output a given PWMsignal before it reverts to the
configured value (M0/M1). If set to 0, there is no timeout. This timeout only affects these pins when
they are configured as PWM output.