AT commands Memory access commands
Digi XBee3® 802.15.4 RF Module User Guide
125
Parameter range
0 - 0xFFFF [read-only]
Default
N/A
FR command
Resets the device. The device responds immediately with an OK and performs a reset 100 ms later.
If you issue FR while the device is in Command mode, the reset effectively exits Command mode.
Parameter range
N/A
Default
N/A
Memory access commands
This section details the executable commands that provide memory access to the device.
AC (Apply Changes)
This command applies changes to all command parameters configured in Command mode.
Any of the following also applies changes the same as issuing an AC command:
n Exiting Command mode with a CN command.
n Exiting Command mode via timeout.
n Receiving a 0x08 API command frame.
n Issuing a 0x08 Local AT Command API frame.
n Issuing a remote 0x17 AT Command API frame with option bit 1 set.
Example: Altering the UART baud rate with the BD command does not change the operating baud
rate until after an AC command is received; at this point, the interface immediately changes baud
rates.
Parameter range
N/A
Default
N/A
WR command
Immediately writes parameter values to non-volatile flash memory so they persist through a power
cycle. Operating network parameters are persistent and do not require a WR command for the device
to reattach to the network.