9) Probe Parameter(Totally 20 items)
10) Hard Limit Parameters(Totally 16 items)
#68 0 BOOL 1/0
0: Disable; 1:mode 1;
2: mode 2; 3: mode 3
#69 1 mm 0~200
#70 0 BOOL 1/0
#71 0 BOOL 1/0
0:current position;
1:fixed position
Initial Postion of the probe sensor
in Mach Coordinate
This parameter group is
used for next probe move
#72
#73
#74
#75
Tool Setting function mode
Thickness of tool sensor
Probe signal electric level
Initial tool's position
Initial probe position on X axis
Initial probe position on Y axis
Initial probe position on Z axis
back distance after probe
0
0
0
5
mm
mm
mm
mm
-9999-9999
-9999-9999
-9999-9999
-9999-9999
#2000 Cutter diameter Cutter/probe sensor diameter
The thickness of the block which
used as Probe Plate.
6
0
0
0
mm 0~999
0~999
0~999
0~999
0~999
0~999
0~999
10~999
-999~999
-999~999
-999~999
-999~999
Tool plate thick for Y mm
shift of X axis before probed 20
-20
mm
Z position before X(Y)-axis probed -5
1
1
1
mm
Back distance when the tool
touches the Y-axis edge
Back distance when the tool
touches the Z-axis edge
mm
center of tool plate 9
20
mm
Tool plate thick for X mm
Tool plate thick for Z mm
shift of Y axis before probed mm
Back distance when the tool
touches the X-axis edge
mm
mm
Probe feedrate mm/min
#2001
#2002
#2003
#2004
#2005
#2006
#2007
#2008
#2009
#2010
#2011
Para.
Mark
Parameter definition
Default
value
Param
Unit
Param
Scope
Notes
0=Low,1=High
#400 Limited siganl active of X--
Limited siganl active of Y--
Limited siganl active of Z--
Limited siganl active of A--
Limited siganl active of X++
Limited siganl active of Y++
Limited siganl active of Z++
Limited siganl active of A++
1 BOOL 1/0
0:Disable; 1:Enable
0:Disable; 1:Enable
0:Disable; 1:Enable
0:Disable; 1:Enable
0:Disable; 1:Enable
0:Disable; 1:Enable
0:Disable; 1:Enable
0:Disable; 1:Enable
#401 1 BOOL 1/0
#402 1 BOOL
BOOL
1/0
1/0#403 1
BOOL 1/01
BOOL 1/01
BOOL 1/01
BOOL 1/01
BOOL 1/00
#404
#405
#406
#407
#408 Effective electric level of X--
Effective electric level of Y--
Effective electric level of Z--
Effective electric level of A--
Effective electric level of X++
Effective electric level of Y++
Effective electric level of Z++
Effective electric level of A++
BOOL 1/00
BOOL 1/00
BOOL 1/00
BOOL 1/00
BOOL 1/0
#409
#410
#411
#412
#413 0
BOOL 1/00
BOOL 1/0
0
#414
#415
Para.
Mark
Parameter definition
Default
value
Param
Unit
Param
Scope
Notes
0=Low; 1=High
0=Low; 1=High
0=Low; 1=High
0=Low; 1=High
0=Low; 1=High
0=Low; 1=High
0=Low; 1=High
0=Low; 1=High
A) #68: 0: disable ;1: Probe of Fix Position Tool Sensor; 2: Probe of Floating Tool Sensor; 3: Probe of Rectangular Block.
B) #2004 .. 2006: This group parameters define the position before probe of each axis. See section 3.3.5.4 for full information.