NIC Quick Reference Guide
51
the test duration, a completion message, indicating that no
problems were found, is printed.
Real-time test settings and accumulated results are not discarded if a
power interruption occurs. The results are saved in 15-minute
increments. When power is restored to the test set, the real-time test will
continue from where it was prior to the power interruption. The power
interruption event will appear in the real-time report.
IMPORTANT
Before starting a real-time test, set the Security System Lock. This will prevent
remote users from accessing the test set while a test is in progress.
To set up and start a real-time test:
1. Select the desired Protocol Processor tab.
2. Select Test and choose Set 1. The Duration and Action After
Duration functions appear.
3. Select Action After Duration. The Select Action after Test
window appears.
4. Select Realtime Actions. The Select Realtime Actions after Test
dialog box appears.
NOTE
The Select Realtime Actions after Test dialog box only contains
realtime actions to choose from when you are working from the
NIC test unit.
5. Select a real-time test option:
Print Events and Repeat Test
Record Events and Repeat Test
Print and Record Events and Repeat Test
Print Events
Record Events
Print and Record Events
The Realtime Setup Parameters window appears.