EasyManua.ls Logo

Digitax X-one - Page 64

Digitax X-one
76 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
The information contained here are property of DIGITAX Automotive Electronics Italy, and extremely confi dential. Any disclosure, copying, distribution to third
party is strictly prohibited.
64
380
Must blank lines prin! ng be avoided?
No / Yes
381
Is thermal printer in usage?
No / Yes
382
Where the thermal printer is connected? (0 = Com 1 1 = Com 2)
No / Yes
383
Enable taximeter-dispatcher connection? - Should the possibility to connect the taximeter with a dispatcher be enabled?
The allowed answer is either: 0 (No: disable) or: 1 (Yes: enable).
No / Yes
384
Dispatcher is connected to COM1 or COM2? - Is the dispatcher connected to COM1 or to COM2 ? See also Q.383 and Q.385 to
Q.387.
The allowed answer is either: 0 (No: COM1) or: 1 (Yes: COM2).
0= COM1
1= COM2
385
COM1 protocol is Digitax or custom? - The protocol used for data-transmission on COM1 is the Digitax protocol or a custom protocol?
See also Q.383, Q.384 and Q.386, Q.387. The allowed answer is either: 0 (No: Digitax protocol) or: 1 (Yes: custom protocol).
0= Digitax
1=
Custom
386
COM2 protocol is Digitax or custom? - The protocol used for data-transmission on COM2 is the Digitax protocol or a custom protocol?
See also Q.383 to Q.385 and Q.387. The allowed answer is either: 0 (No: Digitax protocol) or: 1 (Yes: custom protocol).
0= Digitax
1=
Custom
387
Enable LogIn/LogOut commands? - The questions Q.387 and Q.389 are very much related to each other. They deal with command
execution in relation with th status of being logged-in or logged-out. Their relationship is as follows:
No / Yes
Q.387 Logged-In Q.389 cmd=LogIn Action
No X X - Normal opera! on without limits.
Yes No No - Execute command without answer.
Yes No Yes No Abort Command.
Yes No Yes Yes Change status to Logged-in.
Yes Yes X - Normal opera! on without limits.
The varies items in the tabel have the following meaning:
Logged-In : is the status Logged-In? If No then the status is
Logged-Out.
cmd=LogIn - is the command a Log-In command?
X : This can be either Yes or No; it has no importance.
- : this means that it doesn’t apply.
The allowed answer is either: 0 (No: Enabled) or: 1 (Yes: Disabled).
Q 388 / Available for any possible software extension /
389
During LogOut mode reject commands? - The questions Q.387 and Q.389 are very much related to each other.
They deal with command execution in relation with the status of being logged-in or logged-out. Their relationship is as follows:
No / Yes
Q.387 Logged-In Q.389 cmd=LogIn Action
No X X - Normal opera! on without limits.
Yes No No - Execute command without answer.
Yes No Yes No Abort Command.
Yes No Yes Yes Change status to Logged-in.
Yes Yes X - Normal opera! on without limits.
The varies items in the tabel have the following meaning:
Logged-In : is the status
Logged-In ?
if No then the status is
Logged-Out.
cmd=LogIn : is the
command a Log-In
command ?
X : this can be either
Yes or No; it has no
importance.
- : this means that it
doesn’t apply.
The allowed answer is either: 0 (No: abort command) or: 1 (Yes: execute command (login only).
390
Enable Credit Card authoriza! on numeric fi eld?
No / Yes
391
Baudrate for COM 1: what is the baudrate (transmission-speed) of COM 1? The baudrate is given in baud with an accuracy of 1 baud.
The allowed value goes from 0 (min) to 65535 (max).
0 - 65535
baud
392
Maximum packet length for COM 1: what is the maximum length of a data-packet of COM 1? The packet length is given in byte with an
accuracy of 1 byte. The allowed value goes from 1 (min) to 512 (max).
0 - 512

Table of Contents